CF 50
Manufacturer Schlumberger, France www.schlumberger.com
Status: not in production yet
Meter type heat
Manuf. Radio reading -----------
Communication form for UMR direct connection to internal connector OK
MBUS OK
INFRAopto header OK

Conecting UniMeterRadio module to heat meter CF50

Communication forms:

Stnadart communication interface is MBUS module, otptionally plugged afret opening upper case with screw with montage seal. Power source 3V Li battery. Communication connector is current protected, that's why it's impossible obtain current biger that 5 mA from meter's battery..
Komunikačný protokol je štandartný MBUS protokol. Communication protocol is standart MBUS protocol. Meter react only on its own address, which can be setted after plugin communication module. After plugin communication module is automatically called set-up of MBUS address, baud rate, in case of pulse registering weight and base offset of pulses too. It is possible set address 254. Setup is provided by button and displey.

Namely this characteristics of meter CF50 caused development of micro-programable language for definition of communication with meters. Normally is not here possibility, how can UniMeterRadio module know, which address meter has, only 'manual' setings of communication parameters. If we want do it, from universality we destroy very big part. Altough noted possibility here is for future by the form of download specified configuration of EEPROM, we decide not retreat and go by hard way - construct MBUS scanner directly to UniMeterRadio module. This scanner try communicate with meter at all possible baud rates and through the all possible addreses, so sonn or later meter must answer (if it is physically correct conected) and UniMeterRadio module can set-up and remember actual communication parameters. "Last success" communication parameters serve to any future communication with meter (without needing of again scann) CF50, or any other meter with the same MBUS characteristics.

List of prepared readings:    Detailed description - RadioCF50.pdf     (Log In required)

CF50 actual data Energy 10000xWh Volume 100xl Power 1000xW Flow 1xl/h
00000233400 01 12.04.2005 16:02:46 11912 00096982 000000 000000
Flow 1xl/h InTemp OutTemp days
000000 12.04.05 1630
CF50 Peaks DatTim0 peak0 1000xW DatTim1 peak1 1000xW
00000233400 01 12.04.2005 16:03:18 21.03.02/14:15 69485.9219 31.07.01/12:30 858.967346
peak1 1000xW DatTim2 peak2 1000xW DatTim3 peak3 1000xl/h DatTim4 peak4 1000xl/h DatTim5
858.967346 02.08.01/05:30 705.437988 21.03.02/11:00 414.799988 31.07.01/08:30 67.1999969 02.08.01/08:45
peak5 1000xl/h
53.5999985
CF50 Fixed date rec. period months DatTim_old Energy0 10000xWh Energy1 10000xWh
00000233400 01 12.04.2005 16:03:37 1 31.03.04 11910 11910
Energy1 10000xWh Energy2 10000xWh Energy3 10000xWh Energy4 10000xWh Energy5 10000xWh Energy6 10000xWh Energy7 10000xWh Energy8 10000xWh
11910 11912 11912 11912 11912 11912 11912 11912
Energy9 10000xWh Energy10 10000xWh Energy11 10000xWh Energy12 10000xWh
11912 11912 11912 11912

Actual_data:meter has not connected temperature sensors - by this error it is shorter MBUS protocol - ATTENTION
Reading TRESHOLD is not correctly defined in communication manual from producer ---- after consultation with producer will be included information about results.