  UniMeterRadio system - 433MHz, 868 MHz
En Sk
mainsolutionsnewssupportsitemapcontact
  ***
Introduction UMR System description Databank of connected meters

Reading devices:
  • PSION
  • IPAQ - comming soon
  • GOTIVE - comming soon
  • laptop - working
  • stable station - working
Aplication programs - working
Price and availability - comming soon
Older Docs Case studies
  • Retranslator in Považská Bystrica - (testing phase)
  • Testing UMR in Poprad - (testing phase)
Questionnairy
Partners and Contacts


Sensonic
Manufacturer Ista, Germany www.ista.com
Status: old, not in production
Meter type heat
Manuf. Radio reading -----------
Communication form for UMR direct connection to internal connector -------
MBUS OK
INFRAopto header OK

Connection of UniMeterRadio module to heat meter Sensonic by INFRAhead (fast made cast only as demonstration, the we are able to connect practically anything and anyway communicable, not extisting wire connection is not problem - beaty "bladder-like" infra header comming soon )

Communication forms:

Optiobal modules to Sensonic are determined by plastic height expander, and that's why who have no optional communication module, it is hard buy it and reinstall heat meter. That's why we decide use practically 100% standart interface infra-opto to communicate with UniMetRadio modules.
It expands field of using UniMeterRadio modules without destroying actual possibilities of cooperation with meter. Infra opto header is glue-d by standart stamp doublesided lens, it is removable (for possibility read meter through original ifra opto interface - only in case, that radio module is destroyed, because all, what is readable through the infra opto is readable through the radio too.), it is possible simply stick and un/stick radio module's infra/opto head.
Communication protocol is no-stanndart MBUS protocol, mainly in terms of activating/starting communication. Meter checks communication activity only one time (wake-up period) during the period cca 2.2 seconds, that's why for insuring start of communication it must be 3 seconds long pulse activating. Moreover on one wake-up meter answers only on one request (not waiting for another request). So when it is need use Mbus switch request and when it is only 300 Baud rate here, this meter is one of the slowlest reaction meters.
Reliable answer we give in time cca 8 second, (it's too late for waiting on the side of radio header, if we have not car-accumulator....).
Mainly because this lazy meter we add new function to EEPROM config micro-programm - sending to radio port (which implies in possibility automatic self repeated radio sending of data), and we redefine timing of readings on the level Handlheld-RadioHead.
Ancient concept supposed, that 6 second is period, in frame which are alll meters able to produce measuring data answer.

Not must be, only other view Not must be, only other view

List of prepared readings:    Detailed description - RadioSensonic.pdf     (Log In required)

Sensonic actual data Volume 100xl DatTim_1 DatTim_2 DatTim
00060678017 01 13.04.2005 00:12:09 102502 31.12.02 30.09.03 31.12.03
DatTim OpHours days duration minutes Flowmax_1 1xl/h Powermax_1 1xW Flowmax_2 1xl/h Powermax_2 1xW Flowmax 1xl/h
31.12.03 553 60 0 0 14000 0 0
Powermax 1xW InTemp 1x~C OutTemp 1x~C DeltaT 0,01x~K Energy_1 10000xWh Energy_2 10000xWh Energy 10000xWh
0 113 74 3987 7 0 7
Sensonic archiv data CustNo OpHours days Energy-1 10000xWh DatTim-1
00060678017 01 13.04.2005 00:12:56 60678017 600 140983 29.00.02
DatTim-1 Energy-2 10000xWh DatTim-2 Energy-3 10000xWh DatTim-3 Energy-4 10000xWh DatTim-4 Energy-5 10000xWh
29.00.02 7 31.08.03 249184 31.07.03 249184 30.06.03 249184
DatTim-5 Energy-6 10000xWh DatTim-6 Energy-7 10000xWh DatTim-7 Energy-8 10000xWh DatTim-8
31.05.03 249184 30.04.03 244599 31.03.03 236302 28.02.03